“A PM list should include inspection of electrode surfaces to be sure they are clean and even,” says Klein. “Next is the roll surface. Check for buildup or roll coating damage. Airflow is another critical component to reliable treater operation. Make sure there is no blockage to your airflow, as blocked airflow causes excessive heat. More importantly, you can starve the corona of its much needed oxygen.”